Return list
50HZ

Performance Range

Flow:0m³/h-24m³/h

Head:10-250m

Power:0.75kW-4.4kW


Operating Conditions

◎ Max. ambient temperature<40℃;

◎ Maximum permissible quantity of sand:100g/m³;

◎ hydrogen sulfide content up to 1.5mg/L, chloride ion content up to 400mg/L;

◎ pH 6.5 to 8.5;

◎ Maximum: 70 m below the static water table.


Certificate


Features

Permanent Magnet Synchronous Motor with VFD technology and efficiency increased by 15%-20%; Energy saving and low operating cost with less solar panels needed.

Edible oil filled motor, stable& reliable running with pressure regulating membrane; External controller:

1-IP 44 controller housing for outdoor use;

2-MPPT technology to maximise power use from PV modules;

3-Easy- to-operate LED display panel, monitor the working status of power, voltage and rpm;

4-VFD technology:Automatically operating according to the actual needs to achieve constant pressure and the goal of energy saving.

5-Soft start makes it no impact current, achieving a long service life;

6-Strong protection functions:Over current, over voltage, locked rotor, phase failure and dry run protection functions;

7-Float contorl avialble for automatic using;

8-AC/DC automatic or manual switching(Only available for models with input power P1 above 1.3KW).


Model Instruction

60HZ

Performance Range

Flow:0m³/h-24m³/h

Head:10-250m

Power:0.75kW-4.4kw


Operating Conditions

◎ Max. ambient temperature<40℃;

◎ Maximum permissible quantity of sand:100g/m³;

◎ hydrogen sulfide content up to 1.5mg/L, chloride ion content up to 400mg/L;

◎ pH 6.5 to 8.5;

◎ Maximum: 70 m below the static water table.


Certificate


Features

Permanent Magnet Synchronous Motor with VFD technology and efficiency increased by 15%-20%; Energy saving and low operating cost with less solar panels needed.

Edible oil filled motor, stable& reliable running with pressure regulating membrane; External controller:

1-IP 44 controller housing for outdoor use;

2-MPPT technology to maximise power use from PV modules;

3-Easy- to-operate LED display panel, monitor the working status of power, voltage and rpm;

4-VFD technology:Automatically operating according to the actual needs to achieve constant pressure and the goal of energy saving.

5-Soft start makes it no impact current, achieving a long service life;6-Strong protection functions:Over current, over voltage, locked rotor, phase failure and dry run protection functions;7-Float contorl avialble for automatic using;

8-AC/DC automatic or manual switching(Only available for models with input power P1 above 1.3KW).


Model Instruction