Performance Range
maximum flow: 37L/min, maximum head: 13m
Application Limits
Applied to tap water booster, water heater booster, shower booster and booster between water towers, etc.
Application Fields
◎ Transmission medium: Clear water and other liquids with properties similar to water;
◎ Mediumtemperaturerange:4°C-50°C;ambient temperature:0°C-40°C;
◎ IP grade: IPX4;
◎ Maximum system pressure: 1.0MPa
◎ Medium pH: 6.5-8.5; the volume ratio of solid particles contained in transmission medium shall not exceed 0.1%, and the particle size shall not be greaterthan 0.2mm.
◎ Power supply voltage/frequency: 100-240V/50Hz-60Hz; DC36V.
◎ Installation mode: Horizontally installed along motor shaft.
Features
◎ Power-on start: Forcedly start the water pump for 16S after connecting the power cord and switching on the power.
◎ Automatic boosting: As the water flow signal reaches the start threshold (3L/min), the motor runs; before the water flow signal reaches the shutdown threshold (2L/min), the motor continues to run for pipeline boosting.
◎ Auto off: After water flow signal reaches the shutdown threshold (2L/min), the motor stops running.
Model Instruction